L3 Material Measurement System - Single Test Frame
- Brand: Starrett (USA)
- Starrett L3 systems represent a new and easier solution for creating a test; performing a test; analyzing your test results; and managing test data.
- Used with FMx Series Force Measurement Frames and FLC Load Cell Sensors
Technical Specifications
Features
Download
L3 Systems
Starrett L3 systems represent a new and easier solution for creating a test; performing a test; analyzing your test results; and managing test data.
Test Frames
FMx Series Force Measurement Frames
Specifications | unit | FMS-500 | FMS-1000 | FMS-2500 | FMS-5000 | FMD-10K | FMD-30K | FMD-50K |
Load Capacity | N | 500 | 1000 | 2500 | 5000 | 10,000 | 30,000 | 50,000 |
Minimum Speed | mm/min | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 |
Maximum Speed | mm/min | 1525 | 1525 | 1525 | 1525 | 1525 | 1525 | 752 |
Position Control Resolution |
μm | 0.250 | 0.250 | 0.250 | 0.250 | 0.05 | 0.025 | 0.025 |
Vertical Test Space* | mm | 559 | 953 | 1257 | 1257 | 1270 | 1245 | 1220 |
Total Crosshead Travel | mm | 381 | 762 | 1016 | 1016 | 1162 | 1137 | 1111 |
Throat | mm | 100 | 100 | 100 | 100 | 424 | 424 | 424 |
Accuracy Load Measurement |
Load Cell Sensor Dependent | Load Cell Sensor Dependent | Load Cell Sensor Dependent | Load Cell Sensor Dependent | Load Cell Sensor Dependent | Load Cell Sensor Dependent | Load Cell Sensor Dependent | |
Accuracy Position Measurement** |
(±20 μm) | (±20 μm) | (±20 μm) | (±20 μm) | (±20 μm) | (±20 μm) | (±20 μm) | |
Accuracy Crosshead Speed |
±0.1% of set speed | ±0.1% of set speed | ±0.1% of set speed | ±0.1% of set speed | ±0.1% of set speed | ±0.1% of set speed | ±0.1% of set speed | |
Data Sampling | Hz | 5 to 1000 | 5 to 1000 | 5 to 1000 | 5 to 1000 | 5 to 1000 | 5 to 1000 | 5 to 1000 |
Digital I/O | 8 channels @ 1-5V | 8 channels @ 1-5V | 8 channels @ 1-5V | 8 channels @ 1-5V | 8 channels @ 1-5V | 8 channels @ 1-5V | 8 channels @ 1-5V | |
Operating Temperature |
°C | +10° to +38°C | +10° to +38°C | +10° to +38°C | +10° to +38°C | +10° to +38°C | +10° to +38°C | +10° to +38°C |
Storage Temperature |
°C | -40° to +66°C | -40° to +66°C | -40° to +66°C | -40° to +66°C | -40° to +66°C | -40° to +66°C | -40° to +66°C |
Humidity | +10% to +90%, non-condensing | +10% to +90%, non-condensing | +10% to +90%, non-condensing | +10% to +90%, non-condensing | +10% to +90%, non-condensing | +10% to +90%, non-condensing | +10% to +90%, non-condensing | |
Total Height | mm | 805 | 1218 | 1573 | 1573 | 1685 | 1711 | 1711 |
Total Width | mm | 381 | 381 | 381 | 381 | 787 | 787 | 787 |
Total Depth | mm | 514 | 514 | 514 | 514 | 724 | 724 | 724 |
Weight | kg | 61 | 77 | 88 | 88 | 136 | 192 | 225 |
*Total vertical space is the distance from the top surface of the base plate to the bottom surface of the crosshead, excluding load cell sensor, test fixtures, and clevis adapter.
**Assumes Linear Error Correction and Deflection Compensation has been performed on test frame.
Software Capabilities
Lx System
Lx System Product Comparisons and Capabilities | |||||
Target Applications | L3 | L2 Plus | L2 | S2 | L1 |
Use for Stress, Strain and Material Testing applications | ❍ | ||||
Use for Advanced Load, Distance and Force Analysis applications | ❍ | ❍ | |||
Use for Basic Load, Distance and Force Measurement applications | ❍ | ❍ | ❍ | ❍ | |
Use for Advanced Extension and Compression Spring applications | ❍ | ❍ | |||
Use for Basic Extension and Compression Spring applications | ❍ | ||||
User Interface | |||||
All-In-On Computer Workstation, Windows® OS | ❍ | ❍ | |||
Tablet Computer, Windows® OS | ❍ | ❍ | ❍ | ||
Software Applications | |||||
Test Builder | ❍ | ❍ | ❍ | ✪ | |
Force Quick Test Templates | ❍ | ❍ | |||
Spring Quick Test Templates | ❍ | ||||
Formula Builder | ❍ | ✪ | ✪ | ✪ | |
Automation Builder | ✪ | ✪ | ✪ | ✪ | |
Measurement Methodology | |||||
Measure results using the graph | ❍ | ❍ | |||
Measure results using a List of Value menu | ❍ | ❍ | ❍ | ❍ | |
Create Test Setups using Graphical Test Methods (No programming) | ❍ | ❍ | ❍ | ❏ | |
Create Test Setups using Quick-Test Templates | ❍ | ❍ | ❍ | ||
Test Methods | |||||
Tensile Testing, Load, Distance, Break, Rate | ❍ | ❍ | ❍ | ❏ | ❍ |
Compression Testing, Load, Distance, Break, Rate | ❍ | ❍ | ❍ | ❏ | ❍ |
Hold Testing, Load, Distance for Duration or Event | ❍ | ❍ | ❍ | ❏ | ❍ |
Cyclic Testing for Duration, Count, Loop or Event | ❍ | ❍ | ❍ | ❏ | ❍ |
Shear Testing | ❍ | ❍ | |||
Flexural Testing | ❍ | ❍ | |||
Peel Testing | ❍ | ❍ | |||
Coefficient of Friction Testing | ❍ | ❍ | |||
Spring Testing | ❍ | ❍ | ❍ | ||
Measurement Capabilities | |||||
Measure Stress, Strain, Elongation, Strengths | ❍ | ||||
Measure Offset Yield | ❍ | ||||
Measure Modulus (Elastic, Chord, Tangent) | ❍ | ||||
Measure Strain and Elongation using Extensometer(s) (requires MMx test frames) | ❍ | ||||
Measure Energy, Work, Resilience | ❍ | ❍ | |||
Create Mathematical Expressions using Algebraic, Trigonometric and Logarithmic functions | ❍ | ▷ | |||
Create Basic Expressions using Add, Subtract, Multiple and Divide | ❍ | ▷ | ▷ | ▷ | |
Use Digital I/O | ▷ | ▷ | ▷ | ▷ | |
Use Analog I/O (requires MMx test frames) | ▷ | ▷ | |||
Use Command and Conditional Logic | ▷ | ▷ | ▷ | ▷ | |
Measure Load, Distance, Time | ❍ | ❍ | ❍ | ❍ | ❍ |
Measure Minimum, Maximum and Averages | ❍ | ❍ | ❍ | ❍ | ❍ |
Measure Slopes and Intersections | ❍ | ❍ | |||
Measure Peaks, Valleys, Counts, Averages | ❍ | ❍ | |||
Measure Break, Rupture | ❍ | ❍ | ❍ | ❏ | ❍ |
Measure Delta between results within a test | ❍ | ❍ | ❍ | ||
Measure results within multiple test runs simultaneously (multiview) | ❍ | ❍ | |||
Measure Spring Rate, Spring Constant | ❍ | ❍ | |||
Reporting and Exporting Data | |||||
Print using standard reports, graph, batch, tolerance, statistics | ❍ | ❍ | ❍ | ❍ | ❍ |
Export results/data in .csv for custom reporting | ❍ | ❍ | ❍ | ❍ | ❍ |
Export results/data in .csv for integration with SPC software | ❍ | ❍ | ❍ | ❍ | ❍ |
Include tolerances on any result | ❍ | ❍ | ❍ | ❍ | ❍ |
Note: FMM frames run L1 software only
L3, L2 Plus, L2 and S2 software require a FMS, MMS, FMD or MMD frame
❍ = Standard
✪ = Optional
❏ = Requires Test Builder application
▷ = Requires Automation Builder application
FLC Load Cell Sensors
Starrett offers a full range of precision load cell sensors for material testing, force analysis and force measurement applications. Starrett load cells are compliant with IEEE 1451.4 and meet or exceed ASTM E4, BS 1610, ISO 7500-1 and EN 10002-2.
Measurement accuracies of ±0.05% of reading down to 1/100 of sensor capacity may be achieved.
Three models of s-beam load cell sensors are also available. These are all full bridge, temperature compensated strain gage instruments, designed for force measurement applications, but suitable for some material testing applications.
FLC-P Series - "Premium" S-beam Sensors
Model Number |
Load Capacity (N / KGF / LBF) |
Safe Overload % Full Scale |
FLC-5P | 5 / 0.5 / 1 | 1000 |
FLC-10P | 10 / 1 / 2 | 1000 |
FLC-25P | 25 / 2.5 / 5 | 1000 |
FLC-50P | 50 / 5 / 11 | 1000 |
FLC-100P | 100 / 10 / 22 | 1000 |
FLC-250P | 250 / 25 / 56 | 1000 |
FLC Series - "Sealed" S-beam Sensors
Model Number |
Load Capacity (N / KGF / LBF) |
Safe Overload % Full Scale |
FLC-500 | 500 / 50 / 112 | 150 |
FLC-1000 | 1000 / 100 / 225 | 150 |
FLC-1500 | 1500 / 150 / 337 | 150 |
FLC-2500 | 2500 / 250 / 562 | 150 |
FLC-5K | 5000 / 500 / 1124 | 150 |
FLC-10K | 10,000 / 1000 / 2248 | 150 |
FLC-20K | 20,000 / 2000 / 4500 | 150 |
FLC-E Series - "Economy" S-beam Sensors
Model Number |
Load Capacity (N / KGF / LBF) |
Safe Overload % Full Scale |
FLC-50E | 50 / 5 / 11 | 150 |
FLC-100E | 100 / 10 / 22 | 150 |
FLC-200E | 200 / 20 / 45 | 150 |
FLC-500E | 500 / 50 / 112 | 150 |
FLC-1000E | 1000 / 100 / 225 | 150 |
FLC-2000E | 2000 / 200 / 450 | 150 |
FLC-2500E | 2500 / 250 / 562 | 150 |
FLC-5000E | 5000 / 500 / 1124 | 150 |
Notes
Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1.