https://www.trongkamol.com/product-page/trongkamol-starrett-mkp?lang=th
top of page
 L3 Material Measurement

L3 Material Measurement System - Single Test Frame

  • Brand: Starrett (USA)

 

  • Starrett L3 systems represent a new and easier solution for creating a test; performing a test; analyzing your test results; and managing test data.

 

  • Used with FMx Series Force Measurement Frames and FLC Load Cell Sensors

L3 Systems

Starrett L3 systems represent a new and easier solution for creating a test; performing a test; analyzing your test results; and managing test data.

 

Test Frames

FMx Series Force Measurement Frames

Specifications unit FMS-500 FMS-1000 FMS-2500 FMS-5000 FMD-10K FMD-30K FMD-50K
Load Capacity N 500 1000 2500 5000 10,000 30,000 50,000
Minimum Speed mm/min 0.05 0.05 0.05 0.05 0.05 0.05 0.05
Maximum Speed mm/min 1525 1525 1525 1525 1525 1525 752
Position Control
Resolution
μm 0.250 0.250 0.250 0.250 0.05 0.025 0.025
Vertical Test Space* mm 559 953 1257 1257 1270 1245 1220
Total Crosshead Travel mm 381 762 1016 1016 1162 1137 1111
Throat mm 100 100 100 100 424 424 424
Accuracy
Load Measurement
  Load Cell Sensor Dependent Load Cell Sensor Dependent Load Cell Sensor Dependent Load Cell Sensor Dependent Load Cell Sensor Dependent Load Cell Sensor Dependent Load Cell Sensor Dependent
Accuracy
Position Measurement**
  (±20 μm) (±20 μm) (±20 μm) (±20 μm) (±20 μm) (±20 μm) (±20 μm)
Accuracy
Crosshead Speed
  ±0.1% of set speed ±0.1% of set speed ±0.1% of set speed ±0.1% of set speed ±0.1% of set speed ±0.1% of set speed ±0.1% of set speed
Data Sampling Hz 5 to 1000 5 to 1000 5 to 1000 5 to 1000 5 to 1000 5 to 1000 5 to 1000
Digital I/O   8 channels @ 1-5V 8 channels @ 1-5V 8 channels @ 1-5V 8 channels @ 1-5V 8 channels @ 1-5V 8 channels @ 1-5V 8 channels @ 1-5V
Operating
Temperature
°C +10° to +38°C +10° to +38°C +10° to +38°C +10° to +38°C +10° to +38°C +10° to +38°C +10° to +38°C
Storage
Temperature
°C -40° to +66°C -40° to +66°C -40° to +66°C -40° to +66°C -40° to +66°C -40° to +66°C -40° to +66°C
Humidity   +10% to +90%, non-condensing +10% to +90%, non-condensing +10% to +90%, non-condensing +10% to +90%, non-condensing +10% to +90%, non-condensing +10% to +90%, non-condensing +10% to +90%, non-condensing
Total Height mm 805 1218 1573 1573 1685 1711 1711
Total Width mm 381 381 381 381 787 787 787
Total Depth mm 514 514 514 514 724 724 724
Weight kg 61 77 88 88 136 192 225

*Total vertical space is the distance from the top surface of the base plate to the bottom surface of the crosshead, excluding load cell sensor, test fixtures, and clevis adapter.

**Assumes Linear Error Correction and Deflection Compensation has been performed on test frame.

 

Software Capabilities

Lx System

Lx System Product Comparisons and Capabilities          
Target Applications L3 L2 Plus L2 S2 L1
Use for Stress, Strain and Material Testing applications        
Use for Advanced Load, Distance and Force Analysis applications      
Use for Basic Load, Distance and Force Measurement applications  
Use for Advanced Extension and Compression Spring applications      
Use for Basic Extension and Compression Spring applications        
User Interface          
All-In-On Computer Workstation, Windows® OS      
Tablet Computer, Windows® OS    
Software Applications          
Test Builder  
Force Quick Test Templates      
Spring Quick Test Templates        
Formula Builder  
Automation Builder  
Measurement Methodology          
Measure results using the graph      
Measure results using a List of Value menu  
Create Test Setups using Graphical Test Methods (No programming)  
Create Test Setups using Quick-Test Templates    
Test Methods          
Tensile Testing, Load, Distance, Break, Rate
Compression Testing, Load, Distance, Break, Rate
Hold Testing, Load, Distance for Duration or Event
Cyclic Testing for Duration, Count, Loop or Event
Shear Testing      
Flexural Testing      
Peel Testing      
Coefficient of Friction Testing      
Spring Testing    
Measurement Capabilities          
Measure Stress, Strain, Elongation, Strengths        
Measure Offset Yield        
Measure Modulus (Elastic, Chord, Tangent)        
Measure Strain and Elongation using Extensometer(s) (requires MMx test frames)        
Measure Energy, Work, Resilience      
Create Mathematical Expressions using Algebraic, Trigonometric and Logarithmic functions      
Create Basic Expressions using Add, Subtract, Multiple and Divide  
Use Digital I/O  
Use Analog I/O (requires MMx test frames)      
Use Command and Conditional Logic  
Measure Load, Distance, Time
Measure Minimum, Maximum and Averages
Measure Slopes and Intersections      
Measure Peaks, Valleys, Counts, Averages      
Measure Break, Rupture
Measure Delta between results within a test    
Measure results within multiple test runs simultaneously (multiview)      
Measure Spring Rate, Spring Constant      
Reporting and Exporting Data          
Print using standard reports, graph, batch, tolerance, statistics
Export results/data in .csv for custom reporting
Export results/data in .csv for integration with SPC software
Include tolerances on any result

Note: FMM frames run L1 software only
L3, L2 Plus, L2 and S2 software require a FMS, MMS, FMD or MMD frame

❍ = Standard

✪ = Optional

❏ = Requires Test Builder application

▷ = Requires Automation Builder application

 

FLC Load Cell Sensors

Starrett offers a full range of precision load cell sensors for material testing, force analysis and force measurement applications. Starrett load cells are compliant with IEEE 1451.4 and meet or exceed ASTM E4, BS 1610, ISO 7500-1 and EN 10002-2.

Measurement accuracies of ±0.05% of reading down to 1/100 of sensor capacity may be achieved.

Three models of s-beam load cell sensors are also available. These are all full bridge, temperature compensated strain gage instruments, designed for force measurement applications, but suitable for some material testing applications.

 

FLC-P Series - "Premium" S-beam Sensors

Model Number

Load Capacity 

(N / KGF / LBF)

Safe Overload

% Full Scale

FLC-5P 5 / 0.5 / 1 1000
FLC-10P 10 / 1 / 2 1000
FLC-25P 25 / 2.5 / 5 1000
FLC-50P 50 / 5 / 11 1000
FLC-100P 100 / 10 / 22 1000
FLC-250P 250 / 25 / 56 1000

 

FLC Series - "Sealed" S-beam Sensors

Model Number

Load Capacity 

(N / KGF / LBF)

Safe Overload

% Full Scale

FLC-500 500 / 50 / 112 150
FLC-1000 1000 / 100 / 225 150
FLC-1500 1500 / 150 / 337 150
FLC-2500 2500 / 250 / 562 150
FLC-5K 5000 / 500 / 1124 150
FLC-10K 10,000 / 1000 / 2248 150
FLC-20K 20,000 / 2000 / 4500 150

 

FLC-E Series - "Economy" S-beam Sensors

Model Number

Load Capacity 

(N / KGF / LBF)

Safe Overload

% Full Scale

FLC-50E 50 / 5 / 11 150
FLC-100E 100 / 10 / 22 150
FLC-200E 200 / 20 / 45 150
FLC-500E 500 / 50 / 112 150
FLC-1000E 1000 / 100 / 225 150
FLC-2000E 2000 / 200 / 450 150
FLC-2500E 2500 / 250 / 562 150
FLC-5000E 5000 / 500 / 1124 150

Notes

Load measurement accuracy is ±0.1% of load cell capacity. Display resolution is 10,000:1.

bottom of page