https://www.trongkamol.com/product-page/trongkamol-starrett-mkp?lang=th
top of page
Masterscan 700m

Masterscan 700m

The Masterscan 700M offers the end user a high end narrowband flaw detector with a full VGA display, sync and proportional outputs, sync input and a Spike and Square Pulser.

Typical applications are Weld Fabrication, Corrosion Detection, Composite Inspection, Bond Testing, Forgings & Castings, Power Generation (including EMATS) and general UT inspection.

Sizing Technique Description Standard or Optional
DAC Defined by up to 20 reference points or converted from TCG curve and digitally drawn on the screen. DAC curves meet the requirements of EN, ASME JIS and many other standards. Custom DAC curves can be selected. DAC dynamic range can be extended automatically adjusting the reference curve to match the reference gain. Scanning Gain, and T-Loss available as separate controls. Amplitude readout is selectable between % FSH, % DAC or relative dB. Standard
TCG Time corrected or “Swept” gain, defined by up to 20 reference points or converted from a DAC curve. All points converted to 80% screen height. Option
Backwall Echo (BEA) Attenuation 0-40dB attenuation applied to the latter part of the time base, to improve the detectability of defects near the back wall and loss of BWE due to porosity. Option (requires TCG)
AWS Built in calibration and display of factors and parameters required by AWS D1.1 Option
AVG/DGS Enables the calculation of pseudo “DAC” curve and equivalent reflector size of UT indications, based on user input of transducer parameters. Option
API On-board flaw sizing method in accordance with API 5UE Option
Interface Trigger Unlocks the interface trigger gate controls, which hold off the A-Scan acquisition and display until an interface echo is detected within a specific range and amplitude. Used for the elimination of water-path. Option
Corrosion Software Option Enables complex inspection plans to be uploaded from a PC using the on board UTLity software. Features include 2 dimensional thickness logging, storing A-Logs and B-Logs with thickness values, taking multiple readings per location and note creation for each grid location. B-Scan option available to display bar-growth views of thickness readings taken by Gate 1 against distance or time. Option (Includes B-Scan)
Split DAC & DGS/AVG Adds up to 3 zones of added gain (+12, +24 and +36) to the DAC or DGS/AVG curve to enable single-pass scanning of large sections and attenuative materials conforms to EN583-2:2001. Option

 

bottom of page