MiniTest 2500 / 4500
- BRAND : ElektroPhysik (Germany)
- Classic Design
- Large selection of interchangeable sensors
- IP 65 Rated Rugged housing
Technical Specifications
Features
Download
Technical Specification |
MiniTest 2500 | MiniTest 4500 |
Data memory |
||
Total number of storable readings | 2,000,000 | 2,000,000 |
Max. number of batches | 1 | more than 9500 |
number of application memories for batches with individual calibration |
- | 99 |
number of batches per application memory for batches with identical calibration |
- |
99 |
Statistical functions (per batch) |
kvar, n, max., min. |
kvar, n, max., min., CP, CPK |
Calibration |
Factory settings, zero and up to four calibration points |
1. Factory settings, zero and up to four calibration points 2. Calibration through coating if the base material is not accessible (CTC) |
Offset function |
- |
for addition or subtraction of a constant value to / from the reading |
Limit settings (user definable) with monitoring function | - | Optical and acoustical alert when a limit is exceeded |
Measuring units | µm, mm, cm, mils, inch | µm, mm, cm, mils, inch |
Interface | USB | USB and Bluetooth 4.0 |
Upgradeable interfaces | - |
alarm output, trigger for footswitch, RS 232 interface |
Power supply | 3 x AA (LR06) batteries, USB |
3 x AA (LR06) batteries, USB |
Operating time per battery set approx. | 150 hours (illumination deactivated) | 150 hours (illumination deactivated) |
Norms and standards | DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882; ISO 19840; ASTM B 244, B 499, D 7091, E376 | DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882; ISO 19840; ASTM B 244, B 499, D 7091, E376 |
Display |
53 x 46 mm, backlit |
53 x 46 mm, backlit |
Operating temperature / Storage temperature |
–10 °C … 60 °C / –20 °C … 70 °C |
–10 °C … 60 °C / –20 °C … 70 °C |
Dimensions / Weight |
153 mm x 89 mm x 36 mm (6” x 3.5” x 1.4”) / 320 g (0.7 lbs) (gauge incl. batteries), 90 g (0.2 lbs) rubber protection case |
153 mm x 89 mm x 36 mm (6” x 3.5” x 1.4”) / 320 g (0.7 lbs) (gauge incl. batteries), 90 g (0.2 lbs) rubber protection case |
Protection Class | IP 65 |
IP 65 |
Types of Sensors
Type of Sensor | FN 1.6 | FN 1.6/90 | F 05 | F 3 | N 02 |
Application |
Non-magnetic coatings on steel and insulating coatings on non-ferrous metal.
|
Non-magnetic coatings on steel and insulating coatings on non-ferrous metal.
Also available as version F 1.6/90 only for measuring on magnetic substrate or version N 1.6/90 only for measuring on non-ferrous metals. |
Extremely thin non- ferrous metal, oxide or paint coatings on
|
Non-magnetic coatings on steel, thick paint and enamel
|
The precise solution for very thin insulating layers like lacquer, enamel or anodized layers on non-ferrous metals with high measurement resolution, (0.1 µm) and defined tracking force of just 25 g. |
Technical Data | |||||
Measuring range | 0…1600 µm/65 mils | 0…1600 µm/65 mils | 0…500 µm/20 mils | 0…3000 µm/120 mils | 0…200 µm/8 mils |
Low range resolution | 0.1 µm/0.004 mils | 0.1 µm/0.004 mils | 0.1 µm/0.004 mils | 0.2 µm/0.008 mils | 0.1 µm/0.004 mils |
Guaranteed tolerance (of reading) |
± (1%+1 µm/0.04 mils) * | ± (1%+1 µm/0.04 mils) * | ± (1%+0.7 µm) * | ± (1%+1 µm/0.04 mils) * | ± (1%+0.5 µm/0.02 mils) * |
Minimum radius of curvature |
1.5 mm/0.06 in convex/ 10 mm/0.4 in concave |
flat convex/ 6 mm/0.2 in concave |
0.75 mm/0.03 in convex / 5 mm/0.2 in concave |
1.5 mm/0.06 in convex / 10 mm/0.4 in concave |
1 mm/0.04 in convex / 5 mm/0.2 in concave |
Minimum area for measurement | Ø 5 mm/0.2 in | Ø 5 mm/0.2 in | Ø 3 mm/0.1 in | Ø 5 mm/0.2 in | Ø 2 mm/0.08 in |
Minimum substrate thickness | F 0.5 mm/N 50 μm F 20 mils/N 2 mils |
F 0.5 mm/N 50 μm F 20 mils/N 2 mils |
0.1 mm/4 mils | 0.5 mm/20 mils | 50 μm/2 mils |
Type of Sensor | N 08.Cr | F 10 | F 20 | F 50 | N 10 |
Application |
Special version to measure chrome layers up to 80 μm on copper substrate with minimum thickness of 100 μm. |
Thick coatings like plastic in tank, pipeline and container |
Thick plastic, rubber or |
Very thick corrosion- resistant layers and anti-drumming layers. |
For measurement of insulating layers made of rubber, plastics, glass etc. on non-ferrous metals. |
Technical Data | |||||
Measuring range | 0…80 μm/3 mils | 0…10000 μm/394 mils | 0…20000 μm/790 mils | 0…50000 μm/1970 mils | 0…10000 μm/394 mils |
Low range resolution | 0.1 μm/0.004 mils | 5 μm/0.2 mils | 10 μm/0.4 mils | 10 μm/0.4 mils | 10 μm/0.4 mils |
Guaranteed tolerance (of reading) |
± (1%+1 μm/0.04 mils) * | ± (1%+10 μm/0.4 mils) * | ± (1%+20 μm/0.8 mils) * | ± (3%+50 μm/2 mils) * | ± (1%+2 μm/1 mils) * |
Minimum radius of curvature |
2.5 mm/0.1 in convex / 10 mm/0.4 in concave |
5 mm/0.2 in convex / 16 mm/0.6 in concave |
10 mm/0.4 in convex / 30 mm/1.2 in concave |
50 mm/2 in convex / 200 mm/7.9 in concave |
25 mm/1 in convex / 100 mm/3.9 in concave |
Minimum area for measurement | Ø 5 mm ( 0.2 in) | Ø 20 mm/0.8 in | Ø 40 mm/1.6 in | Ø 300 mm/12 in | Ø 50 m /2 in |
Minimum substrate thickness | 100 μm/4 mils | 1 mm/40 mils | 2 mm/80 mils *(of |
2 mm/80 mils | 50 μm/2 mils |
Type of Sensor | N20 | N100 | F 2 HT |
Application | Insulating coatings, e. g. rubber, plastics, glass on non-ferrous metal.Insulating coatings, e. g. rubber,plastics, glass on non-ferrous metal. | Thick insulating layers and composite materials on non-ferrous metals. |
Special high temperature sensors allow coating thickness measurement on hot surfaces either up to a surface temperature - 250°C / 482° F - 350° C / 662° F. |
Technical Data | |||
Measuring range | 0…20000 μm/790 mils | 0…100000 μm/3940 mils | 0…2000 μm |
Low range resolution | 10 μm/0.4 mils | 100 μm/4 mils | 0.2 μm |
Guaranteed tolerance (of reading) |
± (1%+50 μm/2 mils) * |
± (1%+0.3 μm/12 mils) * | ± (1 %+1 μm) * |
Minimum radius of curvature (convex / concave) |
25 mm/1 in convex/ 100 mm/3.9 in concave |
100 mm/3.9 in convex/ plan |
1.5 mm in convex/ 10 mm in concave |
Minimum area for measurement | Ø 70 mm/2.8 in | Ø 200 mm/78.8 in | Ø 5 mm |
Minimum substrate thickness | 50 μm/2 mils | 50 μm/2 mils | 0.5 mm |
*(of measurement value referring to ElektroPhysik calibration foils)
All Sensors of MiniTest series 1100-4100 are compatible with MiniTest 2500 / 4500
Standard supply
Gauge:
- MiniTest 2500 or 4500
- Plastic transport case
- Rubber protection case
- Manual german, english, french
- 3 x AA battery
- USB connection cable
Sensor:
- Coating thickness sensor at choice
- Set of calibration standards including calibration foils and zero standard