MiniTest 700 Series
- BRAND : ElektroPhysik (Germany)
- Models: MiniTest 725 • 735 • 745
- The intelligent solution for coating thickness measurement
- High precision with various types of devices and sensors
Technical Specifications
Features
Download
Device
Technical specifications | MiniTest 725 • 735 • 745 |
Dual sensors | Automatic recognition of the substrate material with FN sensors |
Data memory |
10 batches for a maximum of 10,000 readings (MiniTest 725 and 735) 100 batches for a maximum of 100,000 readings (MiniTest 745) Memories can be partitioned as needed. |
Statistical evaluation |
Number of readings, min, max, mean value, standard deviation, coefficient of variation, single value statistics, blocks statistics (norm-conforming / freely configurable) |
Calibration modes |
Factory calibration, zero-point-, 2-point-, 3-point-calibration, calibration method “rough” |
Calibration procedures According to internationa standards |
ISO, SSPC, “Swedish”, “Australian” |
Monitoring of limits |
Visual and audible signal output |
Measuring units | Switchable from metric (μm, mm, cm) to imperial (mils, inch, thou) |
Measuring rate |
70 readings per minute in the single mode 20 readings per second in the continuous mode |
Continuous mode | For quick identification of thickness variations |
Operating temperature | – 10 °C ... 60 °C |
Storage temperature | – 20 °C ... 70 °C |
Data interfaces | USB and Bluetooth |
Power supply |
2 pcs batteries, type AA (Mignon); rechargeable NiMH batteries, type AA/HR6 as an option. Battery or rechargeable battery setting option to adapt to the matching nominal voltage |
Norms and standards |
DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882, 19840, ASTM B 244, B 499, D7091, E 376, AS 3894.3, SS 1841 60, SSPC-PA 2 |
Sensors
Measuring Procedure | Sensor Model | Measuring Range | Uncertainty (of reading)* |
Minimum measuringspot | MiniTest 725 | MiniTest 735 | MiniTest 745 |
Magnetic induction sensors |
F 0.5M-0° F 0.5M-45° F 0.5M-90° |
0 ... 0.5 mm | ± (0.5 µm + 0.75 %) | ø 3 mm | x | x | |
Magnetic induction sensors | F 1.5 | 0 ... 1.5 mm | ± (1.0 µm + 0.75 %) | ø 5 mm | x | x | x |
Magnetic induction sensors | F 1.5-90° | 0 ... 1.5 mm | ± (1.0 µm + 0.75 %) | ø 5 mm | x | x | |
Magnetic induction sensors | F 2 | 0 ... 2.0 mm | ± (1.5 µm + 0.75 %) | ø 10 mm | x | x | x |
Magnetic induction sensors | F 2.6 | 0 ... 2.6 mm | ± (1.0 µm + 0.75 %) | ø 5 mm | x | x | x |
Magnetic induction sensors | F 5 | 0 ... 5.0 mm | ± (1.5 µm + 0.75 %) | ø 10 mm | x | x | x |
Magnetic induction sensors | F 15 | 0 ... 15 mm | ± (5.0 µm + 0.75 %) | ø 25 mm | x | x | x |
Eddy current sensors | N 0.3M-0° N 0.3M-45° N 0.3M-90° |
0 ... 0.3 mm | ± (0.5 µm + 0.75 %) | ø 3 mm | x | x | |
Eddy current sensors | N 0.7 | 0 ... 0.7 mm | ± (1.0 µm + 0.75 %) | ø 5 mm | x | x | x |
Eddy current sensors | N 0.7-90° | 0 ... 0.7 mm | ± (1.0 µm + 0.75 %) | ø 5 mm | x | x | |
Eddy current sensors | N 2.5 | 0 ... 2.5 mm | ± (1.5 µm + 0.75 %) | ø 10 mm | x | x | x |
Eddy current sensors | N 7 | 0 ... 7.0 mm | ± (5.0 µm + 0.75 %) | ø 20 mm | x | x | x |
Dual sensors | FN 1.5 | F: 0 ... 1.5 mm N: 0 ... 0.7 mm |
± (1.0 µm + 0.75 %) | ø 5 mm | x | x | x |
Dual sensors | FN 1.5-90° | F: 0 ... 1.5 mm N: 0 ... 0.7 mm |
± (1.0 µm + 0.75 %) | ø 5 mm | x | x | |
Dual sensors | FN 2.6 | F: 0 ... 2.6 mm N: 0 ... 1.0 mm |
± (1.0 µm + 0.75 %) | ø 5 mm | x | x | x |
Dual sensors | FN 5 | F: 0 ... 5.0 mm N: 0 ... 2.5 mm |
± (1.0 µm + 0.75 %) | ø 10 mm | x | x | x |
* Referring tomultipoint calibration
Standard Accessories
- MiniTest, model 725, 735 or 745 SIDSP®-sensor according to choice
- Set with calibration foils and zero reference plate(s)
- Operating instructions in German, English, French and Spanish on a CD-ROM
- Shoulder bag with belt clip
- Batteries (2 pcs, type AA Mignon)
- Manufacturer’s Certificate
- MSoft 7 basic data transfer software