MiniTest 7400
- BRAND : ElektroPhysik (Germany)
- The highest precision coating thickness gauge
- SIDSP® technology for accurate and reproducible readings
- Wide range of external, interchangeable sensors for use in every situation
Technical Specifications
Features
Download
Technical specifications MiniTest 7400 |
|
Max. number of batches | 500 |
Max. number of storable readings | approx. 250,000 readings in total |
Statistics (per batch) |
number of readings, minimum, maximum, average, standard deviation, coefficient of variation, block statistics (norm- conforming/free configurable), process capability indices Cp and Cpk, histogram, trend |
Calibration procedures according to international norms and standards | ISO, SSPC, „Swedish “, „Australian“ |
Calibration |
up to 5 points, user adjustable offset value |
Monitoring of limits | visual and audible alarm to indicate deviations from set limits |
Measuring units |
μm, mm, cm, mils, inch, thou |
Operating temperature | –10°C … 60°C; 14°F … 140°F |
Storing temperature | –20°C … 70°C; -4°F … 158°F |
Data port | IrDA® 1.0, USB and RS232 with optional adapter |
Power supply |
4 x AA (LR06) batteries, or optional power unit (90 – 240 V~ / 48 – 62 Hz) |
Norms and standards |
DIN EN ISO 1461, 2064, 2178, 2360, 2808, 3882, 19840, AS3894; SS 1841 60, SSPC-PA 2, IMO-PSPC, ASTM B 244, B 499, D 7091, E376 |
Display | 160 x 160 pixel LCD with backlight |
Dimensions | 153 mm x 89 mm x 32 mm; 6 inch x 3.5 inch x 1.3 inch |
Weight | 310 g; 11 oz. (gauge incl. batteries) |
MiniTest 7400 Sensors
Sensor Types | F 05 / F 05 HD | F 1.5 / F 1.5 HD | F 1.5-90 | F 2 HD | F 5 / F 5 HD | F 15 | F 35 |
Measuring range | 0 ... 0.5 mm, 20 mils | 0 ... 1.5 mm, 60 mils | 0 ... 1.5 mm, 60 mils | 0 ... 2 mm, 80 mils | 0 ... 5 mm, 200 mils | 0 ... 15 mm, 590 mils | 0 ... 35 m, 1380 mils |
Accuracy (of reading) ¹'⁵ |
+/- (1 μm + 0.75 %) | +/- (1 μm + 0.75 %) | +/- (1 μm + 0.75 %) | +/- (1.5 μm + 0.75 %) | +/- (1.5 μm + 0.75 %) | +/- (5 μm + 0.75 %) | +/- (20 μm + 0.75 %) |
Repeatability (standard deviation of reading) ⁵ |
+/- (0.5 μm +0.5 %) | +/- (0.5 μm +0.5 %) | +/- (0.5 μm +0.5 %) | +/- (0.8 μm +0.5 %) | +/- (0.8 μm +0.5 %) | +/- (2.5 μm +0.5 %) | +/- (10 μm +0.5 %) |
Low range resolution | 0.02 μm | 0.05 μm | 0.05 μm | 0.1 μm | 0.1 μm | 1 μm | 5 μm |
Minimum curvature radius convex ²'⁶ |
1.0 mm | 1.0 mm | - | 1.5 mm | 1.5 mm | 5 mm | 50 mm |
Minimum curvature radius concave ²'⁶ |
7.5 mm | 7.5 mm | 5 mm | 10 mm | 10 mm | 25 mm | 50 mm |
Minimum measuring area without measuring stand ²'⁶ | Ø 14 mm | Ø 14 mm | Ø 10 mm | Ø 14 mm | Ø 14 mm | Ø 25 mm | Ø 100 mm |
Minimum measuring area with measuring stand ²'³'⁶ |
Ø 5 mm | Ø 5 mm | Ø 5 mm | - | Ø 10 mm | Ø 25 mm | - |
Minimum substrate thickness ²'⁶ |
0.3 mm | 0.3 mm | 0.3 mm | 0.5 mm | 0.5 mm | 1.0 mm | 1.5 mm |
Measuring rate in continuous mode | 20 readings/second | 20 readings/second | 20 readings/second | 20 readings/second | 20 readings/second | 20 readings/second | 20 readings/second |
Max. measuring rate in single readings mode |
70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ |
Sensor Types | N 0.2 / N 0.2 HD | N 0.7 / N 0.7 HD | N 0.7-90 | N 2.5 / N 2.5 HD | N 7 |
Measuring range | 0 ... 0.2 mm, 8 mils | 0 ... 0.7 mm, 27 mils | 0 ... 0.7 mm, 27 mils | 0 ... 2.5 mm, 100 mils | 0 ... 7 mm, 280 mils |
Accuracy (of reading) ¹'⁵ |
+/- (1 μm + 0.75 %) | +/- (1 μm + 0.75 %) | +/- (1 μm + 0.75 %) | +/- (1.5 μm + 0.75 %) | +/- (5 μm + 0.75 %) |
Repeatability (standard deviation of reading) ⁵ |
+/- (0.5 μm +0.5 %) | +/- (0.5 μm +0.5 %) | +/- (0.5 μm +0.5 %) | +/- (0.8 μm +0.5 %) | +/- (2.5 μm +0.5 %) |
Low range resolution | 0.02 μm | 0.05 μm | 0.05 μm | 0.1 μm | 1 μm |
Minimum curvature radius convex ²'⁶ | 1.0 mm | 1.0 mm | - | 1.5 mm | 15 mm |
Minimum curvature radius concave ²'⁶ | 7.5 mm | 7.5 mm | 5 mm | 10 mm | 25 mm ⁷ |
Minimum measuring area without measuring stand ²'⁶ | Ø 14 mm | Ø 14 mm | Ø 10 mm | Ø 14 mm | Ø 23 mm |
Minimum measuring area with measuring stand ²'³'⁶ | Ø 5 mm | Ø 5 mm | Ø 5 mm | Ø 10 mm | Ø 20 mm |
Minimum substrate thickness ²'⁶ | 40 μm | 40 μm | 40 μm | 40 μm | 40 μm |
Measuring rate in continuous mode | 20 readings/second | 20 readings/second | 20 readings/second | 20 readings/second | 20 readings/second |
Max. measuring rate in single readings mode | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ |
Sensor Types | FN 1.5 / FN 1.5 HD | FN 1.5-90 | FN 5 / FN 5 HD |
Measuring range | F: 0 ... 1.5 mm, 60 mils N: 0 ... 0.7 mm, 27 mils |
F: 0 ... 1.5 mm, 60 mils N: 0 ... 0.7 mm, 27 mils |
F: 0 ... 5 mm, 200 mils N: 0 ... 2.5 mm, 100 mils |
Accuracy (of reading) ¹'⁵ |
+/- (1 μm + 0.75 %) | +/- (1 μm + 0.75 %) | +/- (1.5 μm + 0.75 %) |
Repeatability (standard deviation of reading) ⁵ |
+/- (0.5 μm +0.5 %) | +/- (0.5 μm +0.5 %) | +/- (0.8 μm +0.5 %) |
Low range resolution | 0.05 μm | 0.05 μm | 0.1 μm |
Minimum curvature radius convex ²'⁶ | 1.0 mm | - | 1.5 mm |
Minimum curvature radius concave ²'⁶ | 7.5 mm | 5 mm | 10 mm |
Minimum measuring area without measuring stand ²'⁶ | Ø 14 mm | Ø 10 mm | Ø 14 mm |
Minimum measuring area with measuring stand ²'³'⁶ | Ø 5 mm | Ø 5 mm | Ø 10 mm |
Minimum substrate thickness ²'⁶ | F: 0.3 mm N: 40 μm |
F: 0.3 mm N: 40 μm |
F: 0.5 mm N: 40 μm |
Measuring rate in continuous mode | 20 readings/second | 20 readings/second | 20 readings/second |
Max. measuring rate in single readings mode | 70 readings per minute⁴ | 70 readings per minute⁴ | 70 readings per minute⁴ |
¹ With multi-point calibration, relating to the supplied standards under laboratory conditions
² With zero calibration and if calibration was made close to the coating thickness to be expected
³ If the precision stand is used, not applicable for HD sensors
⁴ If the „quick“ filter has been selected, measuring rate mainly dependent on handling
⁵ According to DIN 55350 part 13
⁶ With multi-point calibration values better than the specified data can be obtained.
⁷ including coating
* HD stands for Heavy-Duty version
Standard supply
Gauge:
- MiniTest 7400
- MSoft 7 Professional software
- Instructions manual in German, English, French and Spanish
- Short instructions
- 4 AA cells, type LR06
- Plastic carrying case
Sensor:
- SIDSP® sensor according to choice including certificate
- Calibration set with calibration foils and zero reference plate(s)